HomeMy WebLinkAbout2018-04-18 HPC Packeti11watt
THE BIRTHPLACEOFMINNESOTA -'
AGENDA
HERITAGE PRESERVATION COMMISSION MEETING
Council Chambers, 216 Fourth Street North
April 18th, 2018
REGULAR MEETING 7:00 P.M.
I. CALL TO ORDER
II. ROLL CALL
III. APPROVAL OF MINUTES
1. Possible approval of minutes of March 21st, 2018 regular meeting minutes
IV. OPEN FORUM - The Open Forum is a portion of the Commission meeting to address subjects
which are not a part of the meeting agenda. The Chairperson may reply at the time of the
statement of may give direction to staff regarding investigation of the concerns expressed. Out
of respect for others in attendance, please limit your comments to 5 minutes or less.
V. CONSENT AGENDA (ROLL CALL) - All items listed under the consent agenda are
considered to be routine by the Heritage Preservation Commission and will be enacted by one
motion. There will be no separate discussion on these items unless a commission member or
citizen so requests, in which event, the items will be removed from the consent agenda and
considered separately.
2. Case No. 2018-07: Consideration of a Design Review Permit for new business signage for
the property located at 214 Main St S in the CBD District. Mike Lynskey, property owner
and Kathy Lipps, applicant.
3. Case No. 2018-09: Consideration of a Design Review Permit for window replacement for the
property located at 101 3rd St S in the CBD District. Edward Schmidt, applicant.
VI. PUBLIC HEARING
4. Case No. 2018-08: Consideration of a Design Review Permit to build a new single family
home with an attached two car garage located at 107 Everett St S in the RB District. Mark
and Karen Petersen.
VII. OTHER ITEMS OF DISCUSSION
5. National Preservation Month and Preservation Awards (May)
VIII. STAFF UPDATES/FYI
IX. ADJOURNMENT TO THE JOINT HPC AND ADVISORY COMMITTEE MEETING
JOINT HPC AND ADVISORY COMMITTEE MEETING 7:30 P.M.
i \ Ater
THE OIRTNPLACE OF NINNESOTA
HERITAGE PRESERVATION COMMISSION MEETING
March 21, 2018
7:00 P.M.
Chairman Larson called the meeting to order at 7:01 p.m.
Present: Commissioners Goodman, Krakowski, Mino, Welty, Chairman Larson, Council
Representative Junker
Absent: Commissioners Hadrits and Steinwall
Staff: City Planner Wittman
APPROVAL OF MINUTES
Possible approval of February 21, 2018 meeting minutes
Motion by Commissioner Mino, seconded by Commissioner Welty, to approve the minutes of the February 21,
2018 meeting. All in favor, 5-0.
OPEN FORUM
There were no public comments.
CONSENT AGENDA
Case No. 2018-04: An update to the Design Permit for a signage, lighting and outdoor dining plan for
the property located at 402 Main Street South. Corey Burstad of The Elevage Group, property
owner and Christine Pecard, applicant.
Case No. 2018-05: Consideration of a Design Permit for new business signage for the property located
at 232 Main Street South. Yani Abotbul, property owner.
Motion by Commissioner Krakowski, seconded by Commissioner Mino, to adopt the Consent Agenda. All in
favor, 5-0.
NEW BUSINESS
Case No. 2018-06: Consideration of a Design Review Permit for new business signage and exterior painting for
the property located at 226 Main Street South in the DBD District. Gabi Sabongi, property owner and Melissa
Parkos, applicant.
City Planner Wittman stated that the applicant is requesting approval of exterior painting of the existing
sage and white facade elements to black, dark gray and cream; and the installation of one, 36" by 20"
projecting painted wood sign proposed to be hung from the existing wrought iron mount. The sign would
read "Jori & June." The applicant has indicated they may desire to have a metal sign in lieu of wood. On the
basis HPC Case No. 2018-06 conforms to the Downtown Design Review District standards, staff
recommends approval with six conditions.
Heritage Preservation Commission Meeting March 21, 2018
Chairman Larson suggested that the wood slats above the storefront be removed if that is possible to do
without damaging the building. Commissioner Welty suggested if they can't be removed, they could be
painted to match the brick.
Motion by Commissioner Welty, seconded by Commissioner Mino, to approve Case No. 2018-06, Design
Review Permit for new business signage and exterior painting for the property located at 226 Main Street South,
with the six conditions recommended by staff, adding Condition #7 that the wood slats above the storefront
shall be removed or painted to match the brick. All in favor, 5-0.
OTHER ITEMS OF DISCUSSION
Small Wireless future Zoning Text Amendment
Ms. Wittman informed the Commission that staff has completed a legislative version of the Zoning Text
Amendment which would amend six sections of the City Code. In addition to establishing a greater purpose
for right-of-way (ROW) management, tying Design Permitting to the HPC, and an overhaul of the existing
Towers and Antenna Zoning Code section, there are specific sections pertaining to design review and
permitting. She provided an example of a micro -wireless facility. Commission consensus was that it would
be alright for micro -wireless facilities to be approved administratively, if there were a limit on how many
per pole. She will bring the proposed ordinance to the next meeting for further review.
Environmental Resource Management Invitations to Comment
Ms. Wittman reported that the City has received two Invitations to Comment from Environmental
Resources Management (ERM) regarding the future installation of two cellular towers, one of which would
be located in the City of Stillwater. The HPC should comment on the potential affect to historic resources.
There are no historic properties within 500+ feet of the proposed location, therefore staff believes that the
tower will not impact historic properties. The Commission was in agreement.
STAFF UPDATES
2040 Comprehensive Plan Update
City Planner Wittman stated that the City Council has approved a contract with Landscape Research LLC to
assist the HPC with the update of the Historic Resources chapter of the Comprehensive Plan. The update
will be done in conjunction with an HPC advisory committee. Landscape Research LLC is preparing a final
work schedule. It is anticipated the HPC and its committee will meet with the consultants in April, prior to
the HPC's regularly -scheduled meeting.
2018 Commission Appointments and Nominations
Ms. Wit man stated that the seats of Chairman Larson (appointed in 2012) and Commissioner Krakowski
(appointed in 2009) will expire. Commissioner Krakowski has expressed an interest in continuing to serve.
Two new applications have been received to date. She will check with City Clerk Ward about whether
interviews are required and whether two Council members need to interview Chairman Larson for
reappointment.
Chairman Larson suggested the chair should rotate occasionally. Ms. Wittman said the chair is chosen in
May.
National Preservation Month and Preservation Awards (May)
Page 2 of 3
Heritage Preservation Commission Meeting March 21, 2018
City Planner Wittman noted that May is National Historic Preservation month, when the City awards
individuals and organizations whose actions have furthered historic preservation efforts in the community.
She led discussion of possible awardees.
ADJOURNMENT
Motion by Commissioner Goodman, seconded by Chairman Larson, to adjourn. All in favor, 5-0. The meeting
was adjourned at 8:02 p.m.
Respectfully Submitted,
Julie Kink, Recording Secretary
Page 3 of 3
fflwater
!i F 6'.RTFV P14 T; E 91F MINNFSOITA
HERITAGE PRESERVATION COMMISSION
MEETING DATE: April 18, 2017 CASE NO.: 2018-07
APPLICANT: Kathy Lipps, representing Our Bridal Shop
REQUEST: Consideration of a Design Permit for new signage at 214 Main Street
South, in the Downtown Design Review District.
ZONING: Central Business District COMP PLAN DISTRICT: DMU-Downtown Mixed Use
PREPARED BY: Abbi Jo Wittman, City Planner
REQUEST
The applicant is requesting
approval of a Design Permit to
replace an unlit, flat projecting sign
at 214 Main Street South. The sign
will measure 21" tall and 39" in
length. The (approximately) 6
square foot, vinyl or painted
aluminum sign board will read
"Our Bridal Shop". This sign will
replace the business's existing but
the existing bracket will remain.
APPLICABLE REGULATIONS
AND GUIDELINES
Projecting signs are permitted by
the sign ordinance so long as the
sign is no greater than six (6) square
feet. =
Municipal Code Section 31-509,
Design permit states:
• The Standards for Review, Sec.
31-509(f) indicates the HPC shall utilize the following standards:
o Outdoor advertising: The number, location, color, size, height, lighting and
landscaping of outdoor advertising signs and structures in relation to the creation of
traffic hazards and the appearance and harmony with adjacent development.
o Special design guidelines for areas or districts of the city officially adopted by the city
council.
The Downtown Design Manual section pertaining to "Sign and Graphics" is attached for
Commission review.
FINDINGS
This projecting sign uses simple, bold type style lettering in colors that keep with the Victorian
tradition. The sign has sufficient contrast between the black lettering and the ivory background.
While painted wood is encouraged, painted aluminum signs have also been determined to be
consistent with the Downtown Historic District.
ALTERNATIVES
The HPC has alternatives related to this request.
A. Approve. If the proposed application meets the Design Permit standards and the
Downtown Design Review District guidelines, the HPC should move to approve Case
No. 2018-07. Staff recommends the following conditions for approval:
a. The sign shall not be greater than six (6) square feet.
b. If the sign is to be located in the place of an existing sign, the installation shall
utilize existing drill holes for mounting. Any existing drill holes not utilized will
be patched.
c. The sign shall hang a minimum of eight feet off of the public sidewalk area.
d. The sign shall obtain a Sign Permit prior to the installation of the sign.
e. All modifications shall be reviewed and approved prior to be implemented.
Major modifications shall be reviewed by the Heritage Preservation Commission;
minor modifications shall be reviewed by staff.
B. Approve in part.
C. Deny. If the HPC finds that the proposal is not consistent with the Design Permit
standards, and the design review district guidelines, then the Commission may deny the
request. With a denial, the basis of action is required to be given. Furthermore, a denial
with prejudice would prohibit the applicant from resubmittal of a similar application for
one year.
D. Table. If the HPC needs additional information to make a decision, the request may be
tabled to the following meeting.
RECOMMENDATION
Staff recommends conditional approval of HPC Case No. 2018-07 for the Our Bridal Shop
projecting sign.
214 Main Street South
Case No. HPC 2018-07
Page 2 of 3
ATTACHMENTS
Sign Design Specifications
Downtown Design Review District Guidelines (pages 26-33)
214 Main Street South
Case No. HPC 2018-07
Page 3 of 3
3/14/2018 storefront.jpg '] Ur IISA.CLUAr1 , - S
Re\ act vrNe,r\k
dh
Cl-"^'re-ram-
21„hx39"w
48" wide bracket
1U011-u\
�l bkG
k-C-Lr j.s
https://mail. google.com/mail/u/0/#inbox/ 15f92bdc28cccfe l ?projector=1 &messagePartld=0.1
https://mail .google.com/mail/u/0/#search/lebosi gn/15c70fe3330906d 1?projector=1&messagePartld=0.1.7
1/1
1/1
Signs and Graphics
Background
During the peak of commercial activity in Stillwater, the signs in the historic commercial district had a distinct character that was a part of the
overall streetscape. Many of the historic buildings were built to accommodate a storefront sign band in their original design. The efforts of the
Design Manual are not meant to turn back the clock, but rather to preserve and enhance that distinct and historic character of Stillwater. All
signage is subject to Stillwater building and zoning codes.
1. QUANTITIES, LOCATION AND SIZE
Background
In the past, streetscapes had a variety of sign types that not
only identified the business, but also the name of the
buildings, dates of construction, etc. The signs were simple,
bold and well Crafted. Lettering was in clear, no-nonsense
styles, maximizing the contrast between the background
and the lettering.
Varying sign types can be found in the historic streetscape
including: (1) architectural signs, (2) storefront signs, (3)
window signs, (4) awnings, (5) projecting signs, and (6)
painted wall signs and murals. Every building should select
the most appropriate sign type for its architecture and
location.
Guidelines
• The maintenance and restoration of any
existing historic signs is encouraged in lieu of
replacement.
• Signage for a business not located within the
building is not acceptable.
a-
• Only one sign that contains the business name or graphic logo is permitted per street facing side. The exception is that a
window sign may be used in addition to other sign types.
• Signage should be located in such a way as to not obscure any architectural features of the building. A projecting sign with
two faces is considered one sign.
DESIGN MANUAL, COMMERCIAL HISTORIC DISTRICT, STILLWATER, MINNESOTA
26
Signs and Graphics
a. ARCHITECTURAL SIGNS
Backround
Architectural signs are integrated into the building fabric and are constructed of permanent materials such as stone or metal. Names and the dates
of construction were common signs included on the facade. They were typically located in the roof parapet detailing or in a cornerstone detail.
These add a sense of history and place to the character and fabric of Stillwater.
Guidelines
• Preserve existing architectural signs.
• Promote the use of the original building names in new signage.
DESIGN MANUAL, COMMERCIAL HISTORIC DISTRICT, STILLWATER, MINNESOTA
27
Signs and Graphics
b. STOREFRONT SIGNS
Backround
Storefront signs are those which are located on the horizontal band dividing the storefront windows from the upper facade of the building.
Guidelines
• The storefront sign should be used to display the primarily name of the business only. Use only one line of lettering if possible,
leaving out secondary information.
• Use simple, bold lettering with sufficient contrast between the lettering and the background.
• "Trademark" or "Logo" signs may not be acceptable if the color and character of the sign is not in keeping with the historic
character of the area.
• The maximum area of the sign is regulated by the sign ordinance.
• Graphics in the sign are included in the maximum allowable area.
DESIGN MANUAL, COMMERCIAL HISTORIC DISTRICT, STILLWATER, MINNESOTA
28
Signs and Graphics
c. WINDOW SIGNS
Background
Window signs are applied inside the glass of storefront windows, upper floor windows and doorways. Their main focus was on the approaching
pedestrian; therefore the signs gave more detailed information about the business.
Guidelines
• It may often be desirable to keep the display space clear. In these cases, insert the sign at the base or the head of the window, or
both.
• Keep the lettering small remembering that the reader will be in close proximity to the sign. Use several lines where necessaiy
and consider curving the top line at the head of the window.
• Lettering formed with neon may be used in the inside of the window, provided the size, light intensity, color and style are
consistent with the theme of the buildong.
• Total sign area in the window should not exceed one-third of the window area.
• Display street numbers on or directly above the door, and business hours on the inside of the door or in an adjacent window.
'iiiIIIMil
fl;
Trill
.1
1�
1
r
■
t
��
1
P
11
`
DESIGN MANUAL, COMMERCIAL HISTORIC DISTRICT, STILLWATER, MINNESOTA
29
Signs and Graphics
d. PROJECTING SIGNS
Background
Projecting signs are at right angles to the building face, either fixed to the wall or hanging from a bracket. Their major advantage over storefront or
window signs is their ability to be seen by pedestrians and motorists from a distance down the street. If they get too large, however, they can
obscure each other, so it is important to keep them small and simple.
Guidelines
• The maximum area of the sign and the minimum height above the sidewalk is regulated by the sign ordinance.
• Use materials consistent with the period, such as wood signboards and metal brackets.
45 DEGREES
DESIGN MANUAL, COMMERCIAL HISTORIC DISTRICT, STILLWATER, MINNESOTA
30
Signs and Graphics
e. PAINTED WALL SIGNS & MURALS
Background
Painted wall signs occasionally appeared on the side of buildings at comer locations, or where a low adjacent roofline exposed an expanse of plain
brick wall above. As these signs were high on the building, the message was simple and the lettering was large and bold. In the time period of the
1920's — 1950's, there were occasions of painted advertising in these areas. More recently, there have been murals created on walls of "non-
contributing" buildings, or on the bac of "non-contributing" buildings, or on the back walls of "contributing" buildings. These have been
addressed on a case -by -case basis.
Guidelines
• Where existing painted wall signs can still he found, leave them exposed, or restore them to their original colors.
• No new wall signs or murals should he introduced on historic "contributing" buildings.
• Murals on "non-contributing" buildings have been allowed with individual review, provided they have a historic theme, and do
not advertise an existing business or company.
DESIGN MANUAL, COMMERCIAL HISTORIC DISTRICT, STILLWATER, MINNESOTA
31
Signs and Graphics
2. COORDINATION OF SIGNS
Backround
At the time of the commercial boom in Stillwater (1870's — 1900's) most buildings were owned and occupied by single businesses. Merchants
thought of their entire facade as potential sign space. For this reason, the signs were all well coordinated. Ownership and business use patterns
have changed over the years, and many buildings now contain multiple businesses. It is important that tenants and owners cooperate to design a
sign package, which will help to reunify the building facade.
Guidelines
• Multiple -tenant buildings should submit a Sign Package that includes building elevations (drawn to scale), sign types, locations
and sizes. Do not put up signs piecemeal. View the building as a whole and plan a unified design strategy to take advantage of
all possible sign locations.
• Tenants and owners should use a common lettering style and color scheme on the building
• Design the Sign Package to emphasize the whole width and geometry of storefronts and individual buildings. Avoid the use of
unified signage across multiple buildings thai are obviously separate and of different and distinct scale or architecture.
• Consider giving the entire building an identifiable name, i.e. "Stillwater Mercantile", with individual business signs near the
entrances, or on a common directory.
BUILDING SIGN PROGRAM
7-1
E.
Tenant A: 14 sq. ft. sign
Tenant B: 21 sq. ft. sign
Tenant C: 28 sq. ft. sign
Tenant D: 28 sq. ft. sign
Tenant E: 21 sq. ft. sign
DESIGN MANUAL, COMMERCIAL HISTORIC DISTRICT, STILLWATER, MINNESOTA
32
Signs and Graphics
3. MATERIALS
Background
Apart from architectual signs, the original exterior signs of Stillwater were constructed of wood and painted. Window signs were painted, etched
or gilded. Today a great range of materials are available, including metals and plastics, and their unconditioned use can lead to a confusion of
signage, which detracts from the unique character of Stillwater. Modern sign materials are acceptable provided their design is handled with an
understanding of the Victorian spirit. An exception is made in the case of internally lit and back -lit signs, their nature is inherently foreign to the
solid character of brick and wood Victorian architecture and they are bound to strike a false and distracting note in the streetscape.
Guidelines
• Use painted wood where practicable. It is the authentic material and will look appropriate against the weathered brick of
Stillwater's commercial facades. Modern materials that simulate wood may be acceptable, and will be reviewed on a case -by -
case basis.
• Neon may be used as an interior window sign only.
• Backlit and internally lit signs are not appropriate.
• Supporting brackets for projecting signs should be metal, painted black.
DESIGN MANUAL, COMMERCIAL HISTORIC DISTRICT, STILLWATER, MINNESOTA
33
Signs and Graphics
4. SHAPE OF SIGNS
Background
The signs of Stillwater were forthright and utilitarian. Simple, framed rectangular boards were constructed to fill the available spaces. A common
type was the long narrow sign, which stretched across the top of the storefront windows.
Guidelines
• Design the sign shape to fit and fill the available space. Consider using long narrow signs spanning the full width of the facade.
• If a projecting sign is used, keep it simple in shape, small in size and utilitarian in design.
• Window signs should be symmetrical in layout and position. Top lines may be curved.
5. COLOR
Background
The commercial structures of this time period did not use a wide range of paint colors. The palette was particularly narrow; dark green, dark brown
and black were common. Signs were painted for contrast rather than for color -black letters on a white background, gold letters on a black
background. Complete ranges of paint colors are available today, ranging from the jarring to the pastel. If they are used indiscriminately, the
unique historic character of Stillwater will be destroyed.
Guidelines
• Choose subdued colors and dark tones in keeping with the Victorian tradition. Properly selected combinations of dark brown
and green, black, off-white and gold are all appropriate.
• Choose tones with sufficient contrast to be clearly legible: dark on light or light on dark.
• Support brackets of projecting signs should be black.
6. LETTERING
Background
Most of the original signs in Stillwater were strictly practical -the lettering had to be large enough to have an impact at the required viewing
distance, and clear enough to be readily legible. Generally the style was a plain bold or classic uppercase arranged symmetrically, and one style
was often repeated on various signs applied to one building.
Guidelines
• Choose a bold and simple type style and use it on all appropriate signs.
DESIGN MANUAL, COMMERCIAL HISTORIC DISTRICT, STILLWATER, MINNESOTA
34
Signs and Graphics
7. LIGHTING
Background
In the nineteenth century, Stillwater would have been dimly lit. Today we expect our cities to be bright and lively at night. We must achieve an
acceptable standard of lighting without compromising the essential character of the historic setting.
Guidelines
• Use incandescent indirect lighting and place spotlights discreetly, in such a way as to shield the source from pedestrians and
vehicular traffic.
• Neon lights are permitted in window signs only. Design them with respect for the historic ambiance of the area.
• Do not use flashing, moving or intermittent lights.
• Do not use internally or back -lit signs, either projecting, wall mounted, or hung inside the window.
• Do not use changeable or movable letters or graphics.
8. INSTALLATION
Background
With the high turnover of businesses in many of the historic buildings, signage has become temporary in nature. Efforts must be made to make
sure that damage to buildings is minimized when signage is installed.
Guidelines
• The installation of any signage or graphics must have a minimal impact on the building and must allow the building to return
to its original condition upon signage removal.
• Reuse of existing mounting brackets, studs or holes is desirable.
DESIGN MANUAL, COMMERCIAL HISTORIC DISTRICT, STILLWATER, MINNESOTA
35
fflwater
!i F 6'.RTFV P14 T; E 91F MINNFSOITA
HERITAGE PRESERVATION COMMISSION
MEETING DATE: April 18, 2017 CASE NO.: 2018-09
APPLICANT: Edward J. Schmidt, property owner
REQUEST: Consideration of a Design Permit for window replacement for the
structure located at 101 3rd Street South, in the Downtown Design Review
District.
ZONING: Central Business District COMP PLAN DISTRICT: DMU-Downtown Mixed Use
PREPARED BY: Abbi Jo Wittman, City Planner
REQUEST
The applicant is
requesting approval of
a Design Permit to
replace all windows on
the structure with vinyl
wrapped, wood
Anderson 200 series
windows in a sand
finish to match the
existing, upper story
horizontal vinyl siding.
The proposal includes a
slight modification of
the existing, lower level
windows as the 5' wide
by 6' tall window
opening is too large for a double hung window to operate efficiently. Therefore, the application
is proposing the replacement of the single, double hung window with two, double hung
windows separated by a grille.
With the exception of the smallest openings (visually represented as the window on the far left
of the applicant's exterior facade photo), all first story openings on the north and east facades
will be (approximately) 6' tall. The openings, when finished, will have solider coursing and
exterior mulleins in a five over five pattern, as exists today. The upper story windows, where
possible, will be replaced 1:1 with the same level of detail and trim as the lower level windows.
Exterior mulleins will be reduced to between four over four, down to two over two, depending
on the overall window size.
APPLICABLE REGULATIONS AND GUIDELINES
City Code Chapter 34, Building Demolition, indicates demolition is the removal of more than 20%
of the front facade of a structure built prior to 1946 and worthy of such designation because of
its historical, cultural, architectural, archaeological or engineering significance. While the
owner is proposing removing some of the northern facade, this is to create larger window
openings to not only bring greater amounts of sunlight and airflow into the building but to also
help provide for greater design consistency on this facade.
While this is not listed as a contributing building in the Stillwater Commercial Historic District,
the property is subject to the guidelines set forth in the Downtown Design Review Manual. The
manual specifically indicates:
■ The proportion of infill buildings should be sympathetic to the proportion of their
neighbors.
■ Break Up building masses into units of scale that relate to adjacent structures.
■ Design facade details, window openings and entries to conform to approximately the
same proportional patterns of adjacent structures.
FINDINGS
The removal of historic material does not equal 20% or greater of the total northern facade.
Additionally, the new openings and windows will facade details will not only help break up the
building's mass but will also have similar design detail found on the building today.
Additionally, the HPC has previously found vinyl clad, wood windows to be consistent with
the design guidelines of the Downtown Historic District.
ALTERNATIVES
The HPC has alternatives related to this request.
A. Approve. If the proposed application meets the Design Permit standards and the
Downtown Design Review District guidelines, the HPC should move to approve Case
No. 2018-09. Staff recommends the following conditions for approval:
a. The project shall conform to the design plans submitted by the applicant and on
file with this HPC Case No. 2018-09.
b. The windows shall be trimmed in a sand tone finish to match the second story
facade.
c. All window brick openings will have the coursing detail as exists today.
d. The windows shall have exterior mulleins. The patterns shall be five over five on
the lower level to two over two on the upper level.
e. All modifications shall be reviewed and approved prior to be implemented.
Major modifications shall be reviewed by the Heritage Preservation Commission;
minor modifications shall be reviewed by staff.
B. Approve in part.
101 3rd Street South
Case No. HPC 2018-09
Page 2 of 3
C. Deny. If the HPC finds that the proposal is not consistent with the Design Permit
standards, and the design review district guidelines, then the Commission may deny the
request. With a denial, the basis of action is required to be given. Furthermore, a denial
with prejudice would prohibit the applicant from resubmittal of a similar application for
one year.
D. Table. If the HPC needs additional information to make a decision, the request may be
tabled to the following meeting.
RECOMMENDATION
Staff recommends conditional approval of HPC Case No. 2018-09 for the window replacement
project to be located at 101 3rd Street South.
ATTACHMENTS
Exterior Facade Details
Window Specifications (3 pages)
101 3rd Street South
Case No. HPC 2018-09
Page 3 of 3
The Home Depot Special Order Quote
Customer: EDWARD SCHMIDT
Address: 11205 ST CROIX TRL N
STILLWATER, MN 55082
Phone 1: 612-889-9832
Phone 2: 612-889-9832
Email: EDATEKS@ICLOUD.COM
ti
Customer Agreement #: H2801-52205
Printed Date: 4/9/2018
Store: 2801
Associate: MICHAEL
Address: 2360 WHITE BEAR AVE NO
MAPLEWOOD, MN 55109
Phone: 651-770-9600
All prices are subject to change. Customer is responsible for verifying product selections.
Andersen `I 0 Cif 0 � tt b6;
w ,?10044$•000515
d
II awl oatr�
AnWrk:an
Crallsnlari
r>Andrsen
r •4
Pre -Savings Total:
Total Savings:
Pre -Tax Price:
$2,038.06
($305.92)
$1,732.14
Price Valid Through:
4/11/2018
The Home Depot will not accept returns for the below produc
Standard Width = RO: 28" I UNIT: 2
1/2"
Standard Height = RO: 72" I UNIT: 7
1/2"
Frame Width = 27 1/2
Frame Height = 71 1/2
uen##ty. 7 Tot7)•Sa\rings
100-1 200 Series Tilt -Wash Double -Hung Equal Sash , AA , 27.5
x 71.5 , / Sandtone - Pine Unfinished
100-2 Insect Screen 1: 200 Series Tilt -Wash Double -Hung
244DH2460 Full Screen Fiberglass Sandtone PN:0833418
Version:03/01/2018
100-3 Insect Screen 1: 200 Series Tilt -Wash Double -Hung
244DH2460 Full Screen Fiberglass Sandtone PN:0833418
Version:03/01/2018
$766.45
$ 651.40
$34.62 $29.42
$34.62 $29.42
1
1
1
($115.05)
$651
($5.20) $2.9
($5.20) $29
200 Series Tilt -Wash Double -Hung
Overall Joined Rough Opening = 56" x 72"
Overall Joined Unit = 55 1/2" x 71 1/2"
Installation Zip Code = 55109
U.S. ENERGY STAR® Climate Zone = Northern
Search by Unit Code = No
Standard Width = RO: 28" I UNIT: 27 1/2"
Standard Height= RO: 72" I UNIT: 71 1/2"
Frame Width = 27 1/2
Frame Height = 71 1/2
Unit Code = 244DH2460
Frame Depth = 3 1/4"
Venting / Handing = AA
Exterior Color = Sandtone
Interior Species = Pine
Interior Finish Color = Unfinished
Glass Construction Type = Dual Pane
Glass Option = Low-E
High Altitude Breather Tubes = No
Begin Line 100 Descriptions
---- Line 100-1----
Glass Strength = Standard
Glass Tint = No Tint
Specialty Glass = None
Gas Fill = Argon
Unit 1 Lower Glass, 2 Lower Glass: None
Unit 1 Upper Glass, 2 Upper Glass: Finelight
Grilles -Between -the -Glass
Unit 1 Upper Glass, 2 Upper Glass: Colonial
Unit 1 Upper Glass, 2 Upper Glass: Grille Pattern =
Colonial
Unit 1 Upper Glass, 2 Upper Glass: Grille Bar
Width = 3/4"
Unit 1 Upper Glass, 2 Upper Glass: Exterior Grille
Color = Sandtone
Unit 1 Upper Glass, 2 Upper Glass: Interior Grille
Color = Sandtone
Unit 1 Upper Glass, 2 Upper Glass: 3W2H
Grille Alignment Type = Standard Grille Alignment
Lock Hardware Color/Finish = Stone (Factory
Exterior Trim Style = None
Extension Jamb Type = None
Re -Order Item = No
Room Location = None
Unit U-Factor = 0.29
Unit Solar Heat Gain Coefficient (SHGC) = 0.29
U.S. ENERGY STAR Certified = No
Clear Opening Width = 24.56
Clear Opening Height = 32.95
Clear Opening Area = 5.62
Insect Screen 1 Part Number = 0833418
Vertical
Factory
0.5" thick, 71.5" length
SKU = 290067
Vendor Name = S/0 ANDERSEN LOGISTICS
Vendor Number = 60509030
Customer Service = (888) 888-7020
Catalog Version Date = 03/01/2018
Page 1 of 3
Date Printed: 4/9/2018 12:10
Applied)
Window Opening Control Device = No
Security Sensor Type = None
Insect Screen Type = Full Screen
Insect Screen Material = Fiberglass
Insect Screen Color = Sandtone
---- Lines 100-2 to 100-3 have the same description as line 100-1----
Andersen si wiNDuws•Doans
11rr eric in .,.._.ice
Crs�ismail _
End Line 100 Descriptions
200-1 200 Series Tilt -Wash Double -Hung Equal Sash , AA , 35.5
x 71.5 , / Sandtone - Pine Unfinished
200-2 Insect Screen 1: 200 Series Tilt -Wash Double -Hung
244DH3060 Full Screen Fiberglass Sandtone PN:0833434
Version:03/01/2018
00 Series Tilt -Wash Double -Hung
)verall Rough Opening = 36" x 72"
lverall Unit = 35 1/2" x 71 1/2"
nstallation Zip Code = 55109
J.S. ENERGY STAR® Climate Zone = Northern
search by Unit Code = No
standard Width = RO: 36" I UNIT: 35 1/2"
standard Height = RO: 72" I UNIT: 71 1/2"
:rame Width = 35 1/2
:rame Height = 71 1/2
Jnit Code = 244DH3060
rame Depth = 3 1/4"
tenting / Handing = AA
:xterior Color = Sandtone
nterior Species = Pine
nterior Finish Color = Unfinished
ilass Construction Type = Dual Pane
ilass Option = Low-E
$379.77
$322.77
$37.43 $31.81
Begin Line 200 Descriptions
Standard Width = RO: 36" I UNIT: 35
1/2"
Standard Height = RO: 72" I UNIT: 71
1/2"
Frame Width = 35 1/2
Frame Height = 71 1/2
Ot
($57.00)
($5.62)
$322.77
$31.81
---- Line 200-1----
High Altitude Breather Tubes = No
Glass Strength = Standard
Glass Tint = No Tint
Specialty Glass = None
Gas Fill = Argon
Unit 1 Lower Glass: None
Unit 1 Upper Glass: Finelight Grilles -Between -the -
Glass
Unit 1 Upper Glass: Colonial
Unit 1 Upper Glass: Grille Pattern = Colonial
Unit 1 Upper Glass: Grille Bar Width = 3/4"
Unit 1 Upper Glass: Exterior Grille Color =
Sandtone
Unit 1 Upper Glass: Interior Grille Color =
Sandtone
Unit 1 Upper Glass: 3W2H
Grille Alignment Type = Standard Grille Alignment
Lock Hardware Color/Finish = Stone (Factory
Applied)
Window Opening Control Device = No
Security Sensor Type = None
Insect Screen Type = Full Screen
---- Line 200-2 Description is the same as line 200-1 --
End Line 200 Descriptions
Insect Screen Material = Fiberglass
Insect Screen Color = Sandtone
Exterior Trim Style = None
Extension Jamb Type = None
Re -Order Item = No
Room Location = None
Unit U-Factor = 0.29
Unit Solar Heat Gain Coefficient (SHGC) = 0.29
U.S. ENERGY STAR Certified = No
Clear Opening Width = 32.56
Clear Opening Height = 32.95
Clear Opening Area = 7.45
Insect Screen 1 Part Number = 0833434
SKU = 290067
Vendor Name = S/0 ANDERSEN LOGISTICS
Vendor Number = 60509030
Customer Service = (888) 888-7020
Catalog Version Date = 03/01/2018
age 2 of 3
Date Printed: 4/9/2018 12:10 PM
Andersen,
WINDOWS• DOORS
Art erican
Cri Ismail
bAnrMisrn .,;`
300-1 400 Series Double -Hung Equal Sash , AA , 44 x 71.5 , /
Sandtone -Sandtone Pine Unfinished
300-2 Insect Screen 1: 400 Series Double -Hung TW 44 x 71.5
Full Screen Aluminum Sandtone Version:03/01/2018
00 Series Double -Hung
lverall Rough Opening = 44 1/2" x 71 1/2"
)verall Unit = 44" x 71 1/2"
lstallation Zip Code = 55109
I.S. ENERGY STAR® Climate Zone = Northern
earch by Unit Code = No
tandard Width = Custom
tandard Height = Custom
rame Width = 44
rame Height = 71 1/2
'enting / Handing = AA
xterior Color = Sandtone
xterior Sash/Panel Color = Sandtone
iterior Species = Pine
iterlor Finish Color = Unfinished
amb Liner Color = Gray
ilass Construction Type = Dual Pane
ilass Option = Low-E4
ligh Altitude Breather Tubes = No
$730.33
$620.71
$54,84 $46.61
Begin Line 300 Descriptions
Standard Width = Custom
Standard Height = Custom
Frame Width = 44
Frame Height = 71 1/2
1
1
($109.62)
$620.71
($8.23) $46.61
---- Line 300-1----
Glass Strength = Standard
Specialty Glass = None
Gas Fill = Argon
Unit 1 Lower Glass: None
Unit 1 Upper Glass: Finelight Grilles -Between -the -
Glass
Unit 1 Upper Glass: Specified Equal Light
Unit 1 Upper Glass: Grille Pattern = Specified
Equal Light
Unit 1 Upper Glass: Grille Bar Width = 3/4"
Unit 1 Upper Glass: Exterior Grille Color =
Sandtone
Unit 1 Upper Glass: Interior Grille Color =
Sandtone
Unit 1 Upper Glass: 4W2H
DP/PG Upgrade = No
Hardware = None
Lock Hardware Style =Traditional
Number of Sash Locks = 1
Lock Hardware Color/Finish = Stone (Factory
Applied)
Window Opening Control Device = No
Security Sensor Type = None
Insect Screen Type = Full Screen
---- Line 300-2 Description is the same as line 300-1--
End Line 300 Descriptions
Insect Screen Material = Aluminum
Insect Screen Color = Sandtone
Exterior Trim Style = None
Extension Jamb Type = None
Stool Option = None
Re -Order Item = No
Room Location = None
Unit U-Factor = 0.3
Unit Solar Heat Gain Coefficient (SHGC) = 0.28
U.S. ENERGY STAR Certified = No
Clear Opening Width = 40.296
Clear Opening Height = 31.11
Clear Opening Area = 8.706
SKU = 289185
Vendor Name = S/O ANDERSEN LOGISTICS
Vendor Number = 60509030
Customer Service = (888) 888-7020
Catalog Version Date = 03/01/2018
age 3 of 3
Date Printed: 4/9/2018 12:10 PM
fflwater
!i F 6'.RTFV P14 T; E 91F MINNFSOITA
HERITAGE PRESERVATION COMMISSION
MEETING DATE: April 18, 2018 CASE NO.: 2018-08
APPLICANT: Mark & Karen Peterson, property owners
REQUEST:
Consideration of a Design Permit for a new residence to be located in the
Neighborhood Conservation District at 107 Everett Street South, in the
Neighborhood Conservation District (NCD).
ZONING: RB-Two Family COMP PLAN DISTRICT: LMDR-Low/Medium Density
PREPARED BY: Abbi Jo Wittman, City Planner
REQUEST
The applicant is requesting approval of a permit to construct a two and a half story, single-
family residence at 107 Everett Street South, a vacant lot in the Neighborhood Conservation
District. The house will have a single, front facing, asymmetrical 12/12 pitch, gable roof on
both the house and its attached, but recessed garage. The house will be sided with a
combination of dark gray, cement fiber, board and baton and lap siding in cedar or IPE natural
wood. This will be carried on all four sides of the home. The roof areas will have composite
shingles with metal accents over porches, walkways and protruding additions. Windows will
be a gunmetal gray. The house will have an open but covered front stoop and porch with a rear
yard screened porch. It appears that there will be little exposed foundation but what is exposed
to proposed to remain as poured concrete walls.
APPLICABLE REGULATIONS GUIDELINES AND ANALYSIS
All infill homes in the NCD are required to follow the NCD design guidelines. These
design guidelines recommend the following:
Neighborhood and Streets
Massing and scale of a new
A two and a half story home is proposed. The front elevation of
building should be
the home is (approximately) 15' lower in grade than the front of
compatible with neighboring
those homes to the North. The half story look out will be
structures.
situated to the east, giving the appearance of a two-story
residence from the roadway.
Respect the existing rhythm
This property is "tucked away" from most other residences
of the streetscape.
along Everett and Myrtle. Given this, there is not a prevailing
Follow alignment and
setbacks predominant on the
street and adjacent
properties.
street pattern in this location.
The applicants are proposing setbacks consistent with the
zoning code regulations and existing homes. The attached
garage will be set back from the face of the house.
Design new roofs to be
compatible with forms of
existing roofs in the
neighborhood.
Aside from the asymmetrical design, the proposed gable roof is
consistent with the neighboring houses.
Building height should be
considered in choosing roof
forms, architectural style,
and relating to context.
The height of the building is consistent with the zoning code
regulations, as well as the design standards for the district and
adjacent property.
Building and site design
should respond to natural
features.
Preserve significant trees.
The lot largely flat but gradually slopes to an area of steep
slopes on the property. The property owner is proposing to
excavate the property to have a lookout design on the east and
south.
There is one significant tree on the property proposed to be
retained. There is concern from the adjacent neighbor of the
future health of the tree, if its roots are damaged in the
construction of the driveway.
Additionally, there was a mature black walnut that was recently
removed from the top of the steep slope. This was legal and no
permitted was needed. Removal was due to way the tree was
leaning onto the land.
When retaining walls are
necessary, minimize their
impact.
Respect the site's natural
slope in new building
design: minimize cut, fill and
retaining walls.
Retaining walls are proposed on the front of the home. This is
to accommodate for the lookout design proposed. If these walls
are greater than 18" in height, they would be considered
structures and would be required have variances prior to
construction.
While the site does slope to the east and south, the property
owners are proposed significant cut and retaining walls for the
construction of this home.
Building Site
Locate garage and driveway
While the garage will face Everett Street South, it will be
to respect existing street and
situated at greater than 30' from the property line and
neighborhood patterns.
(approximately) 20' behind the front line of the home,
minimizing its impact on the neighborhood.
New driveways may only be 16' at the property line and curb.
Therefore, the applicant will need to reduce the driveway
width, which will help reduce its impact in this area.
Minimize garage impact on
While the garage will be visible from the street, it will be set
107 Everett Street South
HPC Case No. 2018-09
Page 2 of 5
new structure massing and
street front.
back and located on the side of the home.
The size and mass of the
structure should be
compatible with the size of
the property.
The proposal appears to meet all lot coverage requirements for
this zoning district and conforms with the size and mass of the
single residence located at the bottom of South Everett Street.
Consider front porch
elements in the design of
infill structures.
An open front stoop is proposed. However, no porch is
proposed. That said, this is not a traditional neighborhood
streetscape.
Accessory buildings should
be compatible with the main
building.
The attached garage is proposed to have the same materials and
details as the primary structure.
Design and detail new
construction as four-sided
architecture.
This guideline has been met.
Architectural Detail
The facade of the structure
should be compatible in scale
and character to the houses of
the streetscape.
The proposed design is more modern but does not detract from
the neighborhood.
Building elements should be
proportional to the scale and
style of the building, and its
context.
The proposed design is similar in scale and context to
neighboring residences though, with the lookout to the south,
the structure's two and a half story appearance on this facade
will be larger than any adjacent property. That said, the
property's adjacent southern neighbors are located on top of
the bluff, looking down onto this property.
Use architectural details to
create visual interest and
support architectural style.
In new building design,
consider appropriate
materials, textures and
colors, and their relationship
to other buildings of the
neighborhood.
The design is consistent with the architectural style. The
applicant's use a variety of materials and window styles to help
break up the facades of the structure and blend with the
natural setting.
As there are minimal structures in the immediate vicinity of the
proposed residence, there is little relationship to analyze. The
neighbor, directly to the north, will be the most impacted. The
asymmetrical roofline creates a large roof mass along the
northern property line.
Use masonry and stone
authentically.
No masonry or stone is proposed.
PUBLIC COMMENT
One comment has been received to date. Laura Beale (617 Myrtle) has, as noted, expressed
concern for the tree located adjacent to the subject property's western property line,
approximately 4' from the proposed driveway.
107 Everett Street South
HPC Case No. 2018-09
Page 3 of 5
With the reduction of the driveway to 16' in width at the curb and property line, construction
activities should not be located on the tree's root zone, thereby reducing the potentially negative
impact to this tree.
RECOMMENDATION
The HPC has alternatives to the proposal:
A. Approve. If the proposed infill design review meets the Neighborhood Conservation
District guidelines, the HPC should move to approve Case No. 2018-08, with or without
conditions. Staff would recommend the following minimum conditions of approval.
1. With the exception of the conditions outlined herein, plans shall be consistent with
those submitted to the Community Development Department.
2. All 18" or taller retaining walls located in the Front Yard Setback area shall require a
variance prior to construction.
3. The driveway width shall be reduced to 16' at the curb and property line.
4. A building permit shall be obtained prior to the construction of the home.
5. A landscaping plan, to include tree replacement, shall be submitted at the time of the
building permit. All significant trees removed shall be replaced.
6. Exterior lighting shall be submitted for approval prior to the issuance of a building
permit.
7. All minor modifications to the plans shall be approved in advance by the City
Planner. All major modifications shall be approved in advance by the HPC.
Determination of the distinction between "major" and "minor" is defined in the
Zoning Ordinance.
B. Approve in part.
C. Deny. If the HPC finds that the proposal is not consistent with the approved
Neighborhood Conservation District guidelines, then the Commission could deny the
request. With a denial, the basis of the action is required to be given. Furthermore, the
denial would prohibit the applicant from resubmittal of a substantially similar
application within one year.
D. Table. If the HPC needs additional information to make a decision, the requests could be
tabled to the next meeting.
FINDINGS
As noted in the Stillwater Conservation District Design Guideline Manual, The guidelines are
intended to serve as a framework to guide the design process, while allowing for individuality
and creativity in architectural design. While this (more) modern design would not fit within
most traditional neighborhoods in Stillwater, it does not detract from the character of this dead-
end street. With certain conditions, the project substantially conforms to the adopted guidelines
and, therefore, staff recommends approval of HPC Case No. 2018-08 with conditions.
ATTACHMENTS
107 Everett Street South
HPC Case No. 2018-09
Page 4 of 5
Site Location Map
Applicant Narrative
Design Review Checklist
Site Photographs
Certificate of Survey
Site Plan
Elevations
Window Detail
Floor Plans
107 Everett Street South
HPC Case No. 2018-09
Page 5 of 5
H
',,,, ' _•
< 209 ,
H 207
-
Ct
0
z
1 I
(water
,
,
-
-
-, ,.. t—.. ,
--.1..-
16.--
WEST RICE STREET
w 2 r t_ztakiii
>
UJ
ICE ST
"0 _...4i• n9t. it' .....c....... -'
.
;-- • ! ,e.
H
The Birthplace of Minnesota
I ' — \
WTE
1
4 r
_
z,. 1
,s4 „ ..,
...,,
, „...
,, ,,.., / 1,. , .
.. , ,
WEST
.
'
+ '
N\N(
Site Location Map
... , -
, _:, ;
• '
. —r I*
CO
107 Everett Street South
Cn
H MI
2
Cn
H
u)
_1 w
ILI 2
—I
Et
0 115 230 460
Feet
Et F—
f ', 7
ILI
Ct I:
< <
General Site Location
' '
, i
r
1 , 2
,
.
...
/, ......•......... i
8 1 , '
AIi, L
.-`41' 1'"'' '-li4t,.:• 1 72. 8
7• 2. 4 •
-
410 •
o..'
02 8
i
7,
l6. 2,J
-,-„t..
1kt,''
/
WEST
,
.
°
•kte— .
r1'el'11l
a1-c1-.,maaI
i111
,0
..•/
am/4i
,, ..'.-'--r—'
'.
.
•• t.
i
,
,•,,,'• i
' 0 i*
N.
.,
.6 N.
• 1,1,
,-.,.........
. , • .....
I., — ' t
- -, - ."4:•is A A 1
.. ,•,,,, ;-,,,•.,..\ •,,.
= -.,,i,
-- ,
gi 11 r1 .
..
Z
4 . --- 7
,
1
' .• , " . ,
* #
4. '
,.... 4.
Ail . I: exlir- •—•
, • I .011.: fir ...,,, ri, ".._ All,,, =11-r ;,—••—.1. .tir•
• ••-•
,
rt
—4
r
Supplement to Design Review Application
Mark & Karen Vidlock Petersen
107 Everett Street, South, Stillwater
Introduction
Mark & Karen Vidlock Petersen propose to construct a two story home with attached two car garage on
a lot having 12,278 square feet, with 10,998 sf being above steep slopes as defined by City code.
Site
The subject vacant lot is the second lot south of Myrtle Street on Everett Street, which is a short cul-de-
sac at this location. The lot is relatively flat sloping from the NW (highest) to the SE (lowest). There is a
steep slope running along the south side and part of the east side of the lot. Adjacent to the south is
City -owned ravine with no structures. The homes beyond the ravine (on Olive St) are much higher than
the subject lot. The site will need to be raised somewhat on the north side to the elevation of the garage
floor. Grading, cut and fill will be minimal on the south side of the lot.
Design Considerations and Exterior Finishes
In designing the home, particular attention was given to making the house and attached garage blend in
with the character of other Stillwater homes, while still projecting a modern, new house aesthetic. The
two story portion of the house is only 18 feet wide. At ground level, the house has north and south
"wings" that have 4/12 roofs to mimic porches common in the City.
While attached, the garage has the appearance from some angles of being detached, because the roof
of the north "wing" is kept low, which gives the appearance of separation between the house and
garage similar to a detached garage. The overall height is also kept lower by dropping the wall height on
north sides of both the house (5') and garage (8') below customary heights and employing parallel
trusses with a 12/12 pitch to provide internal volume.
The house will be sided in a combination of dark gray board and baton (main house and garage) and lap
siding in either cedar or IPE natural wood. Decks will be either IPE or a TREX equivalent. Deck railings will
be steel with pulled cable. The board and baton areas will be cement fiber board. No vinyl or similar
products will used. Design details are carried through all four sides of the home.
Roofing materials for the lower sloped portions will be either standing seam or click seam steel in a
medium gray. Steeper pitched area will be a similar but darker colored asphalt shingle. Again, this gives
the lower sloped area a feeling of being a porch, even where over conditioned space.
Windows with be Marvin in gunmetal (dark gray). Window detail is provided in the packet of materials
submitted.
Except for lighting on either side of the garage, all exterior lighting will be in soffits. The two lights on
either side of the garage door will be downlit. The driveway will be asphalt.
Impervious Calculations
The subject property is Zone RB, which allows for up to 25% of the area above the slope to be structure
and an addition 25% to be other impervious surface. The area above the slope is 10,998 sf, and thus the
resulting limits are 2749.5 sf. The structure (including house and attached garage) is approximately
2310 sf. The propose driveway is approximately 1330 sf. Other impervious (patios, sidewalks, stairs,
retaining) will be less than 500 sf.
Setbacks
The proposed home is set back 20 feet from the front lot line. The garage is set back more than 10 feet
from the front of the house as required by code. Code also requires all structures to be set back at least
30 feet from the slope on the south and east sides of the lot. As proposed, the screen porch and SE deck
stairs encroach inches into this setback. There is an existing variance for the lot that allows a detached
garage to be within 15 feet of the steep slope, but this variance is not being relied upon.
Landscaping and Trees
Several dead and undesirable trees have already been removed along the east boundary of the lot. A
significant black walnut will be removed on the south lot line because it leans precariously toward the
proposed home. Six to eight trees, a combination of pine, birch and maple, will be planted behind the
garage on the east side of the lot. Further, four to five maples and seedless ash will be added along the
ridgeline and in the front yard.
River rock will be used on the north side of the garage and under all deck areas. The driveway will be the
width of the garage door from the street and be asphalt.
Foundation plantings will be in cedar mulched beds with a combination of shrubs and perennials. It is
currently planned that retaining walls will be poured at the time the foundation is poured. Because of
the design of the walls, they will be only minimally viewable from the street. While the guidelines
encourage natural materials, we believe the poured walls will be aesthetically more in line with the
design of the home.
Design Review Application and Checklist
This Design Review Application and Checklist should be submitted with a City Planning Application Form
Contact: Stillwater City Planning Office 651-430-8821 City Hall 216 N. 4th St. Stillwater, MN 55082
w w w. ci. stillwater. mn. us
Project Address:
) 07 cirdt rl r'
Applicant name address, telephone:
ir7 :lC t K42en/ f li r t 2r6"-
tl 2T TO A ,v i2 €)> 2'Vi
4,4 VN'
1. Neighborhood Architectural Styles:
k Vernacular r P h V ❑ Italianate
Queen Anne L- ❑ Gothic
o Greek Revival ❑ Second Empire
o American Foursquare a Stick ?i, d s /`
a Other: Cos rev- h I e r f�
2. Prevailing neighborhood streetfront
setback: (Guidelines #1, #2, #3)
Prevailing setback on block (est.) 4 / 1 ri-
Average setback on block (est.)
Proposed new house setback - U 44
3. Is the pattern of homes in your
neighborhood 1, 1-1/2, or 2 stories high?
(Guidelines #4, #5)
Stories 1 1-1/2
House on right /vh ❑ ❑
House on left ❑ ❑
House to rear ❑ ❑
Prevailing on block ❑ ❑
Prevailing opposite block ❑ ❑
Proposed new house ❑ ❑
$� witti �O N
4. Prevailing Front Porch pattern in your
neighborhood: (Guideline #13)
Front Porch None
House on right n���} ❑ ❑
House on left �i ❑
House to rear ❑
Prevailing on block ❑
Prevailing opposite block k ❑
Proposed new house !a' ❑
Notes:
5. Prevailing Garage Location pattern in
your neighborhood: (Guidelines #10, #11)
Front Rear Side
House on right
House on left
House to rear
Prevailing on block ❑
Prevailing opposite block ❑
Proposed new house ❑
Garage Garage Garage
ev ❑ ❑ ❑
6. Prevailing Garage Size in your
neighborhood: (Guidelines #10, #11)
1 stall 2 stall 3 stall
Garage Garage Garage
N/A ❑ ❑ ❑
❑ �C ❑
❑ ❑
House on right
House on left
House to rear
Prevailing on block
Prevailing opposite block ❑
Proposed new house ❑
'4 ❑
7. Is the proposed garage compatible in
form and detail with the design character
of the main house? (Guideline #14)
Uts
8. If the proposed structure/garage
location, setbacks, size or general design
character does not fit prevailing
neighborhood patterns, how do you
propose to reduce its impact on the
neighborhood and streetscape? :
("An-13 .L I 73/.�1
CL/ 047 7 , r— l- vt- 4( fie.
4- p f/ 4/ €Cf4t i4ocsE
Stillwater Conservation District
(p 1 of 2) Design Guidelines
Design Review Application and Checklist
9. Does the proposed structure work with
natural slopes and contours of the
property? (Guidelines #6, #7, #8)
X Structure sited parallel to slope
'y(' Building deigned to reduce cut and fill
(minimized retaining walls)
1zt Landscaping incorporated into grading
changes
Notes:
10. Are there significant trees on the
property? Will any trees be removed or
damaged by new construction?
(Guideline #9)
❑ Types of trees
❑ Heights
❑ Trunk diam.
Notes: ,<.e✓t✓o d Qwc e
J s
EP'o or Le)
Aoot._ w,7/ /a-e J
Good Neighbor Considerations
1. Will the proposed structure significantly
affect your neighbor's access to sunlight in
adjacent yards, patios or rooms?
(Guideline #21) �/
House to right:
House to left: _ 62 _
House to rear: 4/0
Notes:
How will you mitigate any negative sunlight
impacts on neighbors?
14 Locate structure on lot to minimize impact
\u Adjust building height, or portions of
building, to minimize impact
❑ Other:
2. Will the proposed structure significantly
affect your neighbors' privacy?(Guidelines
#22, #23)
House to right:
House to left: 0
House to rear: /' U
Notes:
How will you mitigate any negative impacts
on neighbors' privacy?
❑ Offset/locate windows to reduce impact
u Use obscure glass in window
Locate balconies to minimize impact.
X Use landscaping elements for screening
❑ Other:
3. How is outdoor lighting impact
minimized for neighbors?(Guideline #25)
196 Lights are located or directed away from
neighboring property
Light fixtures are shielded to prevent glare
at neighboring property
❑ Other:
To be included with this Application and
Checklist:
❑ Site Plan: include location of proposed
building(s) on property, lot area; indicate
impervious surface, property lines, street/
sidewalk location and approximate
location of adjacent structures. Indicate
proposed outdoor deck/patio and
landscaping features.
❑ B wilding Plan: dimensions, first floor area
square footage.
❑ ng Elevations: indicate building
height, windows, materials, and color on
all elevations. Indicate proposed exterior
lighting.
❑ Photographs of site and streetscape.
❑ Regular Planning Department
Development Application Form
Stillwater Conservation District
Design Guidelines (p 2 of 2)
Photos of Adjacent Properties
110 Everett St S — Across Everett from applicant
Built year unknown (circa 1880)
Extensive remodel in 2004-2006
3 car detached garage (behind house) added 2006
703 Myrtle St W — SW corner of Everett & Myrtle — across and N of applicant
Built 1955
Walkout rambler with two rental units
617 Myrtle St W — SE corner of Everett & Myrtle —adjacent to S of applicant
Built 1868
2 car detached garage (not shown) added to rear in 2004
114 Martha St S — Adjacent to applicant to east (rear)
Built 1875
Detached 2 car garage with lean-to car port.
Site and Streetscape Photos
CERTIFICATE OF SURVEY
FOR: MARK PETERSON
LEGAL DESCRIPTION
(AS SHOWN ON STEWART TITLE GUARANTY
COMPANY AS ISSUED BY ITS AGENT, LAND TITLE, INC.
TITLE COMMITMENT NO. 544938, DATED SEPTEMBER
5TH, 2016)
Lot Six (6), except the North 3.0 feet thereof and Lot
Eight (8), Block Eleven (11), Thompson, Parker, and
Mower's Second Addition, Washington County,
Minnesota. Together with a utility easement over,
under, and across the East 20.00 feet of Lots 2 and 4
and the North 3.00 feet of Lot 6, all in Block 1 1 .
Abstract Property
AREA:
TOTAL LOT AREA 12,278 SQ.FT.
AREA TO TOP OF STEEP SLOPE = 10,998 SQ.FT.
LEGEND
8g1
884.
S8
0�8
N'
0
WALL
CO
63 00
ai
b.-
0,: PP'
59 I , 0" / 885.48'
6S 03 '
CS' X885.6
33,
Q5
766
X 882.7
882
881.
SS\
,
pif
879.7
0
X880.0\6
NORTH
20
CERTIFICATION
X 880.6
40
X 881.7
X 881.4
• ND 1/2"
IRON PIPE
MA•. : RLS
5718
X 879.5
PROJECT LOCATION:
107 EVERETT ST. S.
STILLWATER, MN
PROJECT NO. MPL1 6005
03
4)
X
885.9E
88.
63
U
m
Iw
I-OUND 1/2" 24"--
RON PIPE
MARKED RLS X877.3
25718
I hereby certify that this survey, plan or report was
prepared by me, or under my direct supervision, and
that I am a duly Licensed Land Surveyor under the laws
of the State of MINNESOTA.
DANIEL L. THURMES
X 877.7
874.8
AN
WEST MYRTLE STREET
UTILITIES SHOWN PER PLANS
PROVIDED BY THE CITY OF
STILLWATER, VERIFY
BEFORE CONSTRUCTION.
26
53
F-
Q
z
SIDEWALK
APPROX. ELEv -
=865.3
3' UTILITY
EASEMENT AS
126.00 PLAT RECITED IN LEGAL
V DESCRIPTION.
S89°52'21"E `I`�
5.2126.00 i`,
4 x
5" ! 'ARD SETBACK
LEGEND:
X 882.6
X 880.7
TO 25% SLOPE
X 678.7
876.5
ELINE SETBACK PER
CASE NO. 2012-26, I �
DEP AS DOC. NO. 3N1043g8 / 1/
TOP OF 24% SLOPE - 8/6,
/ X 876.2
- 7-853.6
126.01
N89°51'21"W
126.00 PLAT
SYMBOLS
•
X=G131.6
30�
DESCRIPTION
PROPERTY LINE
EASEMENT LINE
DENOTES IRON MON. FOUND
EXISTING ELEVATIONS
EXISTING CONTOURS
X 872.2
20'
FOUND 1/2"
IRON PIPE
MARKED RLS
25718 -
881.2 X
880.2X
X 875.1
\\
79.1 1
X 875.4
876.4
Suite #1
6750 Stillwater Blvd. N.
Stillwater, MN 55082
Phone 651.275.8969
Fax 651.275.8976
dan@
cssurvey
.net
CORNERSTONE
License No. 25718
Date: 11-3-16
LAND SURVEYING, INC.
XX885 6
X 883.0
X881.7
886.0'
.MIN1i i i
875.33'
X
24" X877.7 ��
X 877.3 c'
GARAGE SLAB:
884.67 CO DOOR
X 876.2
X: .6
O/_.6 n 4
X 882.6
X 880.7
X 878.7
X 876.6
881.2X
/ X876,0�
co
107 Everett St S
Stillwater Minnesota
michael huber architects 03.15.18
West Elevation
107 Everett St S
Stillwater Minnesota
michael huber architects 03.15.18
South Elevation
East Elevation
107 Everett St S
Stillwater Minnesota
michael huber architects 03.15.18
North Elevation
Typical Window Trim
OP
1
Alt
107 Everett St S
Stillwater Minnesota
michael huber architects 03.15.18
1x2 Trim Jambs & Head
-Paint to match siding
Marvin Window
- Finish: GunMetal
1x4 Trim Sill
- Paint to match siding
7/z.
r
c
t
11 [II 111 II
LOWED LEVEL FLOO DLA\
1 j
C3
NORTH
CA".
Petersen
Residence
New Construction
107 Everett St. South
Stillwater, MN 55082
ARCHITECT:
michael,
351 Highview Road
Hudson WI 54016
651 . 442 . 3771
huber
architects
STRUCTURAL ENGINEER:
Bunkers & Associates
6687 Forest Street
Farmington, MN 55024
651.366.2853
Copyright 2018, michael huber architects
All Rights Reserved. Copying, reproduction or
distribution prohibited without express written
permission.
Project No.:
Date:
Revisions:
3/6/18
Title
LOWER LEVEL
PLAN
Sheet Number
Al
2
I—
L
../
I
o
1
1
rn
0
7
IJ 111 111 1I
Ir J
n n n n n
L
V AI \ LEVEL ELOO PLA\
L
C
1
—I —
NORTH
C..
Petersen
Residence
New Construction
107 Everett St. South
Stillwater, MN 55082
ARCHITECT:
michael
351 Highview Road
Hudson WI 54016
651 . 442 . 3771
huber
architects
STRUCTURAL ENGINEER:
Bunkers & Associates
6687 Forest Street
Farmington, MN 55024
651.366.2853
Copyright 2018, michael huber architects
All Rights Reserved. Copying, reproduction or
distribution prohibited without express written
permission.
Project No.:
Date:
Revisions:
3/6/18
Title
MAIN LEVEL
PLAN
Sheet Number
A2
1 /4"=1'-0"
r
F
L 1
11 11 11--11 11--11
1
t
r
-w
11 I
L
0
17
1
UPPED LEVEL ELOO PLA\
/4"=1'-0"
--J
J
NORTH
("A".
Petersen
Residence
New Construction
107 Everett St. South
Stillwater, MN 55082
ARCHITECT:
michael
351 Highview Road
Hudson WI 54016
651 . 442 . 3771
huber
architects
STRUCTURAL ENGINEER:
Bunkers & Associates
6687 Forest Street
Farmington, MN 55024
651.366.2853
Copyright 2018, michael huber architects
All Rights Reserved. Copying, reproduction or
distribution prohibited without express written
permission.
Project No.:
Date:
Revisions:
3/6/18
Title
UPPER LEVEL
PLAN
Sheet Number